abstract: "This article describes an interesting case of automated implantable cardioverter defibrillator (AICD) extrusion fifteen months after implantation. The case report is followed by a discussion of the causes and treatment of skin erosion following pacemaker/AICD insertion.\n"
altloc:
- http://www.ipej.org/0404/shapiro.htm
chapter: ~
commentary: ~
commref: ~
confdates: ~
conference: ~
confloc: ~
contact_email: ~
creators_id: []
creators_name:
- family: Shapiro
given: Michael
honourific: ''
lineage: ''
- family: Hanon
given: Sam
honourific: ''
lineage: ''
- family: Schweitzer
given: Paul
honourific: ''
lineage: ''
date: 2004-10
date_type: published
datestamp: 2005-04-13
department: ~
dir: disk0/00/00/41/86
edit_lock_since: ~
edit_lock_until: ~
edit_lock_user: ~
editors_id: []
editors_name:
- family: Singh
given: Balbir
honourific: ''
lineage: ''
- family: Lokhandwala
given: Yash
honourific: ''
lineage: ''
- family: Francis
given: Johnson
honourific: ''
lineage: ''
- family: Gupta
given: Anup
honourific: ''
lineage: ''
eprint_status: archive
eprintid: 4186
fileinfo: /style/images/fileicons/application_pdf.png;/4186/1/shapiro.pdf|/style/images/fileicons/text_html.png;/4186/2/shapiro.htm
full_text_status: public
importid: ~
institution: ~
isbn: ~
ispublished: pub
issn: ~
item_issues_comment: []
item_issues_count: 0
item_issues_description: []
item_issues_id: []
item_issues_reported_by: []
item_issues_resolved_by: []
item_issues_status: []
item_issues_timestamp: []
item_issues_type: []
keywords: "pacemaker complication, skin erosion, extrusion\n"
lastmod: 2011-03-11 08:55:54
latitude: ~
longitude: ~
metadata_visibility: show
note: ~
number: 4
pagerange: 213-216
pubdom: TRUE
publication: Indian Pacing and Electrophysiology Journal
publisher: Indian Pacing and Electrophysiology Group
refereed: TRUE
referencetext: |-
1. Kiviniemi MS, Pirnes MA, Eranen HJ, Kettunen RV, Hartikainen JE. Complications related to permanent pacemaker therapy. Pacing & Clinical Electrophysiology. 1999;22(5):711-20.
2. Cohn JD, Santhanam R, Rosenbloom MA, Thorson RF. Delayed pacemaker erosion due to electrode seal defects. Annals of Thoracic Surgery. 1979;28:445-450.
3. Smyth NPD, Millette ML. Complications of pacemaker implantation. In: Barold SS, ed. Modern Cardiac Pacing. Mount Kisco, NY: Futura Publishing Co; 1985:257–304.
4. Da Costa A, Kirkorian G, Cucherat M, Delahaye F, Chevalier P, Cerisier A, Isaaz K, Touboul P. Antibiotic prophylaxis for permanent pacemaker implantation: a meta-analysis. Circulation. 1998 May 12;97(18):1796-801.
5. Griffith MJ, Mounsey JP, Bexton RS, Holden MP. Mechanical, but not infective, pacemaker erosion may be successfully managed by re-implantation of pacemakers. Br Heart J. 1994;71:202–205.
6. Pavia S, Wilkoff B. The management of surgical complications of pacemaker and implantable cardioverter-defibrillators. Curr Opin Cardiol. 2000;16:66-71.
7. Hurst LM, Evans HB, Winale B, Klein GJ. The salvage of infected cardiac pacemaker pockets using a closed irrigation system. Pacing & Clinical Electrophysiology. 1986;9:785-792.
relation_type: []
relation_uri: []
reportno: ~
rev_number: 14
series: ~
source: ~
status_changed: 2007-09-12 16:56:34
subjects:
- ipej
succeeds: ~
suggestions: ~
sword_depositor: ~
sword_slug: ~
thesistype: ~
title: 'A Rare, Late Complication after Automated Implantable Cardioverter-Defibrillator Placement'
type: journalp
userid: 4424
volume: 4