creators_name: Roy TN, Sunil creators_name: Sankar, Vikram creators_name: Francis, Johnson creators_name: Tada, Hiroshi editors_name: Singh, Balbir editors_name: Lokhandwala, Yash editors_name: Francis, Johnson editors_name: Gupta, Anup type: journalp datestamp: 2005-08-11 lastmod: 2011-03-11 08:56:08 metadata_visibility: show title: Tissue Tracking Imaging for Identifying the Origin of Idiopathic Ventricular Arrhythmias: A New Role of Cardiac Ultrasound in Electrophysiology ispublished: pub subjects: ipej full_text_status: public keywords: Tissue tracking imaging; Ventricular tachycardia; Earliest color-coded signal; Myocardial motion amplitude; Speckle tracking abstract: Several strategies for mapping ventricular outflow tract tachycardia have been reported as useful indices for differentiating between those originating from the right and the left side. Recently, tissue tracking imaging (TTI) has been demonstrated as a novel non-invasive modality for identifying the origin of outflow tract tachycardias. Tissue tracking imaging is an ultrasonographic technique that measures the myocardial motion amplitude towards the transducer in each region during systole, identifying regional myocardial displacement on the basis of myocardial velocities using color Doppler myocardial imaging principles. In this technique, the origin of the arrhythmia could be recognized as the site where the earliest color-coded signal (ECCS) appeared on the myocardium at the onset of the systole. In preliminary studies this modality was found to be useful in differentiating out flow tract ventricular tachycardias. ECCS was always found below or at the level of the pulmonary valve in all arrhythmias which could be ablated from the right ventricular outflow tract, while in those where the origin was above the pulmonary valve could be ablated from the left sinus of valsalva. These results indicate that TTI can provide detailed and accurate information on the arrhythmia origin of OT-VT and may be useful for differentiating between an OT-VT originating from the LV epicardium remote from the LSV and that from the LSV. Newer advances in echocardiographic technologies like high resolution, high frame rate real time three dimensional echocardiography with speckle tracking may further improve the precise localization of arrhythmias in the future. date: 2005-07 date_type: published publication: Indian Pacing and Electrophysiology Journal volume: 5 number: 3 publisher: Indian Pacing and Electrophysiology Group pagerange: 155-159 refereed: TRUE referencetext: 1. Coggins DL, Lee RJ, Sweeney J, Chein WW, Van Hare G, Epstein L, Gonzalez R, Griffin JC, Lesh MD, Scheinman MM. Radiofrequency catheter ablation as a cure for idiopathic tachycardia of both left and right ventricular origin. J Am Coll Cardiol 1994;23:1333-1341. 2. Kamakura S, Shimizu W, Matsuo K, Taguchi A, Suyama K, Kurita T, Aihara N, Ohe T, Shimomura . Localization of Optimal Ablation Site of Idiopathic Ventricular Tachycardia from Right and Left Ventricular Outflow Tract by Body Surface ECG Circulation 1998 98: 1525 - 1533. 3. Kanagaratnam L,Tomassoni G,Schweikert R,Pavia S,Bas D,Beheiry S,Niebauer M, Saliba W,Chung M,Tchou P,Natale A.Ventricular tachycardias arising from the aortic sinus of Valsalva:An under-recognized variant of left outflow tract ventricular tachycardia.J Am Coll Cardiol 2001;37:1408-1414. 4. Yoshida Y, Hirai M, Murakami Y, Kondo T, Inden Y, Akahoshi M, Tsuda M, Okamoto M, Yamada T, Tsuboi N, Hirayama H, Ito T, Toyama J, Saito H. Localization of precise origin of idiopathic ventricular tachycardia from the right ventricular outflow tract by a 12-lead ECG: a study of pace mapping using a multielectrode "basket" catheter.Pacing Clin Electrophysiol. 1999;22(12):1760-8. 5. Ribbing M, Wasmer K, Monnig G, Kirchhof P, Loh P, Breithardt G, Haverkamp W, Eckardt L. Endocardial mapping of right ventricular outflow tract tachycardia using noncontact activation mapping. J Cardiovasc Electrophysiol. 2003;14(6):602-8. 6. Ito S, Tada H, Naito S, Kurosaki K, Ueda M, Hoshizaki H, Miyamori I, Oshima S, Taniguchi K, Nogami A. Development and validation of an ECG algorithm for identifying the optimal ablation site for idiopathic ventricular outflow tract tachycardia. J Cardiovasc Electrophysiol. 2003;14(12):1280-6. 7. Tuzcu V. ECG algorithm for idiopathic ventricular outflow tract tachycardia. J Cardiovasc Electrophysiol. 2003;14(12):1287-8. 8. Betts TR, Roberts PR, Allen SA, Morgan JM. Radiofrequency ablation of idiopathic left ventricular tachycardia at the site of earliest activation as determined by noncontact mapping. J Cardiovasc Electrophysiol. 2000;11(10):1094-101. 9. Fung JW, Chan HC, Chan JY, Chan WW, Kum LC, Sanderson JE. Ablation of nonsustained or hemodynamically unstable ventricular arrhythmia originating from the right ventricular outflow tract guided by non contact mapping. Pacing Clin Electrophysiol. 2003; 26(8):1699-705. 10. Tada H, Toide H, Naito S, Ito S, Kurosaki K, Kobayashi Y, Miyaji K, Yamada M, Oshima S, Nogami A, Taniguchi K. Tissue tracking imaging as a new modality for identifying the origin of idiopathic ventricular arrhythmias.Am J Cardiol 2005;95:660-664. 11. Borges AC, Kivelitz D, Walde T, Reibis RK, Grohmann A, Panda A, Wernecke KD, Rutsc W, Hamm B, Baumann G. Apical tissue tracking echocardiography for characterization of regional left ventricular function:comparison with magnetic resonance imaging in patients after myocardial infarction.J Am Soc Echocardiogr 2003;16:254-262. 12. Tada H. Idiopathic Epicardial Ventricular Arrhythmias: Diagnosis and Ablation Technique from the Aortic Sinus of Valsalva. Indian Pacing Electrophysiol. J. 2005;5(2): 96-105. [Free Full Text] 13. Pan C, Hoffmann R, Kuhl H, Severin E, Franke A, Hanrat P. Tissue tracking allows rapid and accurate visual evaluation of left ventricular function. Eur J Echocardiogr 2001;2:197-202. 14. Thomas G. Tissue Doppler echocardiography –A case of right tool,wrong use. Cardiovasc Ultrasound 2004; 12.2(1):12. 15. Edvardsen T, Urheim S, Skulstad H, Steine K, Ihlen H, Smiseth OA. Quantification of left ventricular systolic func-tion by tissue Doppler echocardiography. Circulation 2002; 105:2071-8. 16. Ingul C B, Torp H, Aase S A, Berg S, Stoylen A, Slordahl S A. Automated analysis of strain rate and strain: feasibilty and clinical implications. J Am Soc Echocardiogr 2005;18:411-8 citation: Roy TN, Sunil and Sankar, Vikram and Francis, Johnson and Tada, Hiroshi (2005) Tissue Tracking Imaging for Identifying the Origin of Idiopathic Ventricular Arrhythmias: A New Role of Cardiac Ultrasound in Electrophysiology. [Journal (Paginated)] document_url: http://cogprints.org/4486/1/roy.htm document_url: http://cogprints.org/4486/2/roy.pdf