---
abstract: The anaesthetic laryngoscope Airtraq is designed for the difficult airway. This disposable laryngoscope requires minimal cervical manipulation and unlike other common anaesthetic larynmgoscopes contains a channel for the guidance of an endotracheal tube. This could also be used for diagnosis and biopsy under a general anaesthetic or potentially under a local anaesthetic in an outpatient setting for biopsies or the removal of hypopharyngeal foreign bodies via flexible biopsy forceps obviating the need for a general anaesthetic. Thus Airtraq could be included in the armoury of pre-existing direct laryngoscopes because of its virtue of minimal airway manipulation.
altloc:
- http://www.ojhas.org/issue38/2011-2-16.htm
chapter: ~
commentary: ~
commref: ~
confdates: ~
conference: ~
confloc: ~
contact_email: ~
creators_id:
- dulanimendis@yahoo.com
- ~
creators_name:
- family: Mendis
given: 'D '
honourific: ''
lineage: ''
- family: Oates
given: J
honourific: ''
lineage: ''
date: 2011-07-30
date_type: published
datestamp: 2012-11-09 17:37:20
department: ~
dir: disk0/00/00/79/73
edit_lock_since: ~
edit_lock_until: 0
edit_lock_user: ~
editors_id:
- BS Kakkilaya
editors_name:
- family: Kakkilaya
given: Srinivas
honourific: Dr
lineage: ~
eprint_status: archive
eprintid: 7973
fileinfo: application/pdf;http://cogprints.org/7973/1/2011%2D2%2D16.pdf
full_text_status: public
importid: ~
institution: ~
isbn: ~
ispublished: pub
issn: ~
item_issues_comment: []
item_issues_count: ~
item_issues_description: []
item_issues_id: []
item_issues_reported_by: []
item_issues_resolved_by: []
item_issues_status: []
item_issues_timestamp: []
item_issues_type: []
keywords: Difficult intubation; Laryngoscopy
lastmod: 2012-11-09 17:37:20
latitude: ~
longitude: ~
metadata_visibility: show
note: ~
number: 2
pagerange: ~
pubdom: TRUE
publication: Online Journal of Health and Allied Sciences
publisher: BS Kakkilaya
refereed: TRUE
referencetext: "1.\tAmerican Society of Anesthesiologists. Practice guidelines for management of the difficult airway. A report by the American Society of Anesthesiologists Task Force on Management of the Difficult Airway. Anesthesiology. 1993;78(3):597-602.\r\n2.\tAmerican Society of Anesthesiologists. Practice Guidelines for Management of the Difficult Airway. An Updated Report by the American Society of Anesthesiologists Task Force on Management of the Difficult Airway. Anesthesiology. 2003;98(5):1269–1277.\r\n3.\tMaharaj CH, Buckley E, Harte BH, Laffey JG. Endotracheal Intubation in Patients with Cervical Spine Immobilization. A Comparison of Mackintosh and Airtraq Laryngoscopes. Anesthesiology. 2007;107(1):53-59.\r\n4.\tDhonneur G, Ndoko SK, Amathieu R, Housseini LE, Polliand C, Tual L. A comparison of two techniques for inserting the Airtraq laryngoscpe in morbidly obese patients. Anaesthesia. 2007;62:774-777.\r\n5.\tDhonneur G, Ndoko SK, Amathieu R, Housseini LE, Poncelet C, Tual L. Tracheal Intubation Using the Airtraq in Morbid Obese Patients Undergoing Emergency Cesarean Delivery. Anesthesiology. 2007;106(3):629-630.\r\n6.\tNdoko SK, Amathieu R, Tual L, Polliand C, Kamoun W, Housseini LE, Champault G, Dhonneur G. Tracheal intubation of morbidly obese patients: a randomised trial comparing performance of Macintosh and Airtraq laryngoscopes. British Journal of Anaesthesia. 2008;100(2):263-268.\r\n7.\tSuzuki A, Toyama Y, Iwasaki H. Correspondence: Airtraq for awake tracheal intubation. Anaesthesia. 2007;62:744-755.\r\n8.\tMaharaj CH, Costello JF, Higgins BD, Harte BH, Laffey JG. Learning and performance of tracheal intubation by novice personnel: a comparison of the Airtraq and Mackintosh laryngoscope. Anaesthesia. 2006;61:671-677."
relation_type: []
relation_uri: []
reportno: ~
rev_number: 10
series: ~
source: ~
status_changed: 2012-01-25 14:01:44
subjects:
- OJHAS
succeeds: ~
suggestions: ~
sword_depositor: ~
sword_slug: ~
thesistype: ~
title: The Application of Airtraq (fibreoptic intubation device) to Otolaryngology
type: journale
userid: 4338
volume: 10